                      | Instrumentation Valves |  |  |  
                |  |  
                | Ball Valve |  
                |  |  
                | Check Valve |  
                |  |  
                | Double Block & Bleed Valve |  
                |  |  
                | Gauge Valve |  
                |  |  
                | Manifold Valve |  
                |  |  
                | Mono Flange Valve |  
                |  |  
                | Needle Valve |  
                |  |  
                | Plug Valve |  
                |  |  
                | Pressure Relief Valve |  
                |  |  
                | Vent & Bleeder Valve |  
                |  |  |  | 
              
                | Manifold Valve |  
                |  |  
                | 2 Valve Manifold Pipe To Flange Tee Type |  
                |  |  
                |  |  
                |  |  
                | 
                  
                    
                      | Tubefit part no. | H | W | H1 | L | Size | CV | ORIFICE |  
                      | 2VM-TT-PF |  |  |  |  |  |  |  |  |  
                |  |  
                | Features : |  
                | 
                  
                    |  | 2 valve manifolds are designed for remote or separate mounting. |  
                    |  | Connecting from process side 1/2" npt(f) and instrument side 1/2" npt(f) connecting system impulse lines and transmitters, having simple two  valves configuration which allows for easy block or isolate, bleed or vent valve callbration of a static pressure transmitter or gauge. |  |  
                |  |  
                | Bonnet Assembly : |  
                | 
                    
                      |  | Bonnet : back seated blow out proof. |  
                      |  | Spindle : ground and thread rolled. Packing below thread. |  
                      |  | Spindle Tip : non-rotating tip shut-off type & soft seated. |  
                      |  | Dust cap : dust cap protects stem threads from external contamination heat code traceability. |  |  
                |  |  
                | Technical specifications : |  
                | 
                  
                    |  | Size : 1/4" & 1/2" |  
                    |  | End Connection : NPT, BSPT, BSP & Socket Weld. |  
                    |  | Working Pressure : 6000 psi (413 bar) |  
                    |  | Temperature Rating : PTFE 450° f(232°c) Grafoil 700° f (371°c") |  
                    |  | Material of Construction : SS 316l, SS 316, SS 304, C.S, F11,hastelloy,monel |  
                    |  | Optional sour gas service valves are available confirming to nace mr-01-75 |  
                    |  | Stem Packing : PTFE, Grafoil. |  
                    |  | Orifice : ø4.7 |  
                    |  | All valves are 100% factory tested prior to shipment. |  |  
                |  |  
                | Testing : |  
                | 
                    
                      |  | Pneumatic seat test is performed at 1/4 of working pressure. Hydrostatic shell test is performed at 1.5 times the working pressure optional test are available upon request. |  |  
                |  |  
                | Lubrication : |  
                | 
                    
                      |  | Molybdenum   disulphide  (mo  s2) |  |  |